43dBm Wireless Coupling Tetra VHF UHF Fiber Optic Repeater Our tetra repeates have CE 0865 certificate with report,freely to import to European! This repeater is mainly applicable to such case: Underground fiber optic cable network already exists beneath the area to be covered;there is huge obstructive terrain between the BTS and the area to be covered;the distance between the BTS and the area to be covered is 20 km around.
1.Aluminum alloy enclosure for excellent heat dissipation,waterproof design for all-weather installation; 2.Adopting filter with highly selectivity and low insertion loss eliminates interference between uplink and downlink; 3.Modules structure,full-duplex & dual-port design, and built-in power supply,easy for maintenance and installation; 4.High linearity PA; high system gain; 5.ALC and AGC to ensure stable operation; 6.Max transmission distance between Donor Unit and Remote Unit is 20KM; 7.Local PC GUI operation and Optional Remote Modem control. 8.Can support up to 8 pcs RU with 1 pcs MU
Typical applications
wireless coupling  Fiber Optic Repeater for-application Â
Main Specification
Master Unit for wireless couplingÂ
Main Item
Specification(on user requirement)
UpLink
DownLink
Frequency Range
CDMA850
824 ~ 849 MHz
869~ 894MHz
GSM&EGSM
880 ~ 915 MHz
925 ~ 960 MHz
DCS1800
1710 ~ 1785 MHz
1805 ~ 1880 MHz
PCS1900
1850 ~ 1910 MHz
1930~ 1990 MHz
WCDMA2100
1920 ~ 1980 MHz
2110 ~ 2170 MHz
AWS2100
1710 ~ 17555 MHz
2110 ~ 2155 MHz
IDEN
806 ~ 821Mhz
851 ~ 866 Mhz
TETRA
 350 ~380 Mhz Â
380 ~410Â Mhz
Customized frequency
Customized frequency
LTE
700MHZ(A,B,C,D band optional
2500 ~ 2570 MHz
2620 ~ 2690 MHz
Customized frequency
Customized frequency
Bandwidth
5MHz (Cavity Filter)
Maximum Gain
55dB±2dB
55dB±2dB
ALC
Output increment will not exceed 2dB when input increase 10dB
Frequency Error
≤±0.5ppm
Gain Control Range
0~30dB
RF Output Power
37dBm
10dBm
Noise Figure
≤5dB
Group Delay
≤5us
Inband Flatness
≤3dB
Intermodulation attenuation
Inband
≤-45dBc/30KHz
Outband               (0ff 2.5MHz)
≤-36dBm/30KHz@9KHz-1GHz
≤-30dBm/30KHz@1GHz-12.75GHz
Outband Rejection
Selective Channel
≤-30dBc/30kHz@±200kHz
≤-60dBc/30kHz@±400kHz
BroadBand
≤-40dB@2.5MHz
 ≤-60dB@10MHz
Selective Band
≤-30dBc/30kHz@±400kHz
≤-60dBc/30kHz@±600kHz
Spurious emissionÂ
≤-36dBm/30KHz@9KHz-1GHz
≤-30dBm/30KHz@1GHz-12.75GHz
VSWR
≤1.5
Power Supply
220VAC,110VAC,48VDC,24VDC
Size
Normal Cabinet
450mm x325mm x220mmÂ
Die-Casting Cabinet
610mmx440mmx250mm
Weight
Normal Cabinet
20Kg
Die-Casting Cabinet
38Kg
Work temperature
-40ºC~+55ºC or -25ºC~+65ºC
Relative humidity
≤95%
Operation Configuration
LCD Display, Manual Key-press, PC RS232 Port,
Others
Refer to user manual for more specification
Fiber Connector
FC/APC or SC/APC
Fiber Mode
Single mode
Optic Wavelength
1310nm or 1550nm
Optic Output Power
2dBm±2dBm
   Slave Unit  RU
Main Item
Specification(on user requirement)
UpLink
DownLink
Frequency Range
CDMA850
824 ~ 849 MHz
869~ 894MHz
GSM&EGSM
880 ~ 915 MHz
925 ~ 960 MHz
DCS1800
1710 ~ 1785 MHz
1805 ~ 1880 MHz
PCS1900
1850 ~ 1910 MHz
1930~ 1990 MHz
WCDMA2100
1920 ~ 1980 MHz
2110 ~ 2170 MHz
AWS2100
1710 ~ 17555 MHz
2110 ~ 2155 MHz
IDEN
806 ~ 821Mhz
851 ~ 866 Mhz
TETRA
 350 ~380 Mhz Â
380 ~410Â Mhz
Customized frequency
Customized frequency
LTE
700MHZ(A,B,C,D band optional
2500 ~ 2570 MHz
2620 ~ 2690 MHz
Customized frequency
Bandwidth
5MHz (Cavity Filter)
Maximum Gain
55dB±2dB
55dB±2dB
ALC
Output increment will not exceed 2dB when input increase 10dB
Frequency Error
≤±0.5ppm
Gain Control Range
0~30dB
RF Output Power
10dBm
43dBm
Noise Figure
≤5dB
Group Delay
≤5us
Inband Flatness
≤3dB
Intermodulation attenuation
Inband
≤-45dBc/30KHz
Outband                (0ff 2.5MHz)
≤-36dBm/30KHz@9KHz-1GHz
≤-30dBm/30KHz@1GHz-12.75GHz
Outband Rejection
Selective Channel
≤-30dBc/30kHz@±200kHz
≤-60dBc/30kHz@±400kHz
BroadBand
≤-40dB@2.5MHz
 ≤-60dB@10MHz
Selective Band
≤-30dBc/30kHz@±400kHz
≤-60dBc/30kHz@±600kHz
Spurious emissionÂ
≤-36dBm/30KHz@9KHz-1GHz
≤-30dBm/30KHz@1GHz-12.75GHz
VSWR
≤1.5
Power Supply
220VAC,110VAC,48VDC,24VDC
Size
Normal Cabinet
450mm x325mm x220mmÂ
Die-Casting Cabinet
610mmx440mmx250mm
Weight
Normal Cabinet
20Kg
Die-Casting Cabinet
38Kg
Work temperature
-40ºC~+55ºC or -25ºC~+65ºC
Relative humidity
≤95%
Operation Configuration
LCD Display, Manual Key-press, PC RS232 Port,
Others
Refer to user manual for more specification
Fiber Connector
FC/APC or SC/APC
Fiber Mode
Single mode
Optic Wavelength
1310nm or 1550nm
Optic Output Power
2dBm±2dBm
3. Structure Diagram Â
4. Product ImageÂ
Monitor Function
1)Detection Function Uplink and downlink attenuation; Uplink output power; Optical communication module status; The uplink and downlink output over-power and under-power threshold;Power amplifier switching; Downlink power amplifier status; 2)Control Function Uplink and downlink attenuation; Downlink output threshold; The uplink and downlink output over-power and under-power threshold; Downlink VSWR threshold; Power amplifier switching; Channel setting;
Site Survey
Before you install, the installer should contact the person responsible for the project, understand whether there are installed conditions in the installation site.
Specifically include: Installation site, surroundings (Temperature and Humidity), power supply, and so on. If qualified, should go live on-site survey with related personnel. The repeater is designed that can working outdoors, operating temperature is -25ºC~65ºC, humidity is ≤95%, which can be adapted to most areas of the natural environment.
Recommended Environmental Requirements:
1.Installation area non-corrosive gases and fumes, Electromagnetic interference field strength ≤140dBμV/m(0.01MHz~110000MHz). 2.Mounting height should facilitate the RF cable routing, cooling, safety and maintenance. 3.Should provide a set of independent and stable 150VAC~290VAC(Nominal 220V/50Hz)AC Power. It must not be shared with other high-power appliances telecommunications equipment. 4.Lightning protection devices must be installed in the building, and it should have sufficient strength and stability. 5.There are grounding bar in the vicinity.
Installation Tools
Installation tool to use: Electric impact drill, iron hammer, pulleys, ropes, belts, helmets, ladders, screwdriver, hacksaw, knife, pliers, wrenches, compass, measuring tape, tweezers, electric iron, portable PC, 30dB directional coupler, spectrum analyzers, VSWR tester.
Repeater installation
   Fixed safety and reliability;    The interface is connected correctly;    Reliable waterproof sunscreen, tape winding direction from bottom to top, in order to facilitate drainage;    Fixed height in order to facilitate the operation and not easy to be destroyed; The Donor unit and remote unit can use pole installation or wall installation. According to the structure size of the equipment, use steel wire or the expansion screw to fix the machine on the upright rod or a wall. Equipment bottom height is generally 1.2 meters.         Â
Antenna and Feeder Installation and Precautions
1.Installation of antenna systems requires experienced professionals to complete. 2.You can not install an antenna near power lines, which may be life-threatening. 3.All exposed joints must use self-adhesive waterproof tape and electrical insulation tape seal securely.
Optical Fiber Connection Description
The Donor unit connect to the remote unit through the optical fiber, therefore, optical fiber jumper type selection is very important when connecting, If the fiber jumpers do not match each other, connection will cause the loss of optical signal of different degree, cause open station failure. In general the repeater station in the engineering application, there are two types of connection terminal, one is called FC/PC, and the other is called FC/APC. The difference between them is the head types, PC type head connecting surface is flat, APC type connecting surface inclined 8 degrees tilt. In engineering, the simple discrimination method is to observe the connection head protective rubber sleeve color, green is APC, black is PC. APC/FC and PC/FC connectors are connected to each other will cause the optical transmission loss more than 10 to 20dB, therefore, in the project, different color head connected is strictly forbidden. Conversion between the two types of joints can be realized only by the optical fiber jumper.
43dBm Wireless Coupling Tetra VHF UHF Fiber Optic Repeater Our tetra repeates have CE 0865 certificate with report,freely to import to European! This repeater is mainly applicable to such case: Underground fiber optic cable network already exists beneath the area to be covered;there is huge obstructive terrain between the BTS and the area to be covered;the distance between the BTS and the area to be covered is 20 km around.
1.Aluminum alloy enclosure for excellent heat dissipation,waterproof design for all-weather installation; 2.Adopting filter with highly selectivity and low insertion loss eliminates interference between uplink and downlink; 3.Modules structure,full-duplex & dual-port design, and built-in power supply,easy for maintenance and installation; 4.High linearity PA; high system gain; 5.ALC and AGC to ensure stable operation; 6.Max transmission distance between Donor Unit and Remote Unit is 20KM; 7.Local PC GUI operation and Optional Remote Modem control. 8.Can support up to 8 pcs RU with 1 pcs MU
Typical applications
wireless coupling  Fiber Optic Repeater for-application Â