Model NO.: ACSR
Wire Core Material: Aluminum Conductor Steel Reinforced
Certification: IEC DIN
Model: ACSR
Brand: Rne Da
Trademark: RNE DA
Transport Package: Standard Export Drum
Specification: DIN48201
Origin: Hebei, China
HS Code: 8544492100
Model NO.: ACSR
Wire Core Material: Aluminum Conductor Steel Reinforced
Certification: IEC DIN
Model: ACSR
Brand: Rne Da
Trademark: RNE DA
Transport Package: Standard Export Drum
Specification: DIN48201
Origin: Hebei, China
HS Code: 8544492100
Aluminum Clad Steel Reinforced ACSR
ACSRÂ conductor
ASTM B232 standard Merlin acsr conductorÂ
ACSR,AAC,AAAC,ASCSR&ACAR conductor widely used in power transmission lines with various voltage levels. since they have such goodÂ
characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are alsoÂ
suitable for laying across rivers and valleys where special geographical teatures exist.
Â
1. Specification:
Â
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
 Â
ACSR British Sizes BS215-1 |
Code name |
Nominal Al. Area |
Stranding and Wire diameter |
Sectional area of Al. |
Total sectional area |
Overall diameter |
Calculated Breaking Load |
Calculate D.C Resistance at 20 |
Final modulus of elasticity |
mm2 |
Al. |
Steel |
mm2 |
mm2 |
mm |
daN |
/km |
hbar |
Mole |
10 |
6/1.50 |
1/1.50 |
10.52 |
4.50 |
43 |
414 |
2.706 |
7900 |
Squirrel |
20 |
6/2.11 |
1/2.11 |
20.94 |
6.33 |
85 |
788 |
1.368 |
7900 |
Gopher |
25 |
6/2.36 |
1/2.36 |
26.24 |
7.08 |
106 |
961 |
1.093 |
7900 |
Weasel |
30 |
6/2.59 |
1/2.59 |
31.61 |
7.77 |
128 |
1146 |
0.9077 |
7900 |
Fox |
35 |
6/2.79 |
1/2.79 |
36.66 |
8.37 |
149 |
1320 |
0.7822 |
7900 |
Ferret |
40 |
6/3.00 |
1/3.00 |
42.41 |
9.00 |
172 |
1520 |
0.6766 |
7900 |
Rabbit |
50 |
6/3.35 |
1/3.35 |
52.88 |
10.05 |
214 |
1835 |
0.5426 |
7900 |
Mink |
60 |
6/3.66 |
1/3.66 |
63.18 |
10.98 |
255 |
2180 |
0.4545 |
7900 |
Shunk |
60 |
12/2.59 |
7/2.59 |
63.27 |
12.95 |
465 |
5300 |
0.4567 |
10500 |
Beaver |
70 |
6/3.99 |
1/3.99 |
74.82 |
11.97 |
302 |
2570 |
0.3825 |
7900 |
Horse |
70 |
12/2.79 |
7/2.79 |
73.37 |
13.95 |
538 |
6120 |
0.3936 |
10500 |
Racoon |
75 |
6/4.10 |
1/4.10 |
79.20 |
12.30 |
320 |
2720 |
0.3622 |
7900 |
Â
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204
Â
(1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182Â
(2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel  wire(s) with aluminum wires surrounded by one orÂ
more layers of helically. Greased ACSR can also be supplied.Â
(3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels
Â
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49,Â
DIN480201, JIS C3109, customer special specification also can be satisfied.Â
Aluminum Clad Steel Reinforced ACSR
ACSRÂ conductor
ASTM B232 standard Merlin acsr conductorÂ
ACSR,AAC,AAAC,ASCSR&ACAR conductor widely used in power transmission lines with various voltage levels. since they have such goodÂ
characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are alsoÂ
suitable for laying across rivers and valleys where special geographical teatures exist.
Â
1. Specification:
Â
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
 Â
ACSR British Sizes BS215-1 |
Code name |
Nominal Al. Area |
Stranding and Wire diameter |
Sectional area of Al. |
Total sectional area |
Overall diameter |
Calculated Breaking Load |
Calculate D.C Resistance at 20 |
Final modulus of elasticity |
mm2 |
Al. |
Steel |
mm2 |
mm2 |
mm |
daN |
/km |
hbar |
Mole |
10 |
6/1.50 |
1/1.50 |
10.52 |
4.50 |
43 |
414 |
2.706 |
7900 |
Squirrel |
20 |
6/2.11 |
1/2.11 |
20.94 |
6.33 |
85 |
788 |
1.368 |
7900 |
Gopher |
25 |
6/2.36 |
1/2.36 |
26.24 |
7.08 |
106 |
961 |
1.093 |
7900 |
Weasel |
30 |
6/2.59 |
1/2.59 |
31.61 |
7.77 |
128 |
1146 |
0.9077 |
7900 |
Fox |
35 |
6/2.79 |
1/2.79 |
36.66 |
8.37 |
149 |
1320 |
0.7822 |
7900 |
Ferret |
40 |
6/3.00 |
1/3.00 |
42.41 |
9.00 |
172 |
1520 |
0.6766 |
7900 |
Rabbit |
50 |
6/3.35 |
1/3.35 |
52.88 |
10.05 |
214 |
1835 |
0.5426 |
7900 |
Mink |
60 |
6/3.66 |
1/3.66 |
63.18 |
10.98 |
255 |
2180 |
0.4545 |
7900 |
Shunk |
60 |
12/2.59 |
7/2.59 |
63.27 |
12.95 |
465 |
5300 |
0.4567 |
10500 |
Beaver |
70 |
6/3.99 |
1/3.99 |
74.82 |
11.97 |
302 |
2570 |
0.3825 |
7900 |
Horse |
70 |
12/2.79 |
7/2.79 |
73.37 |
13.95 |
538 |
6120 |
0.3936 |
10500 |
Racoon |
75 |
6/4.10 |
1/4.10 |
79.20 |
12.30 |
320 |
2720 |
0.3622 |
7900 |
Â
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204
Â
(1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182Â
(2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel  wire(s) with aluminum wires surrounded by one orÂ
more layers of helically. Greased ACSR can also be supplied.Â
(3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels
Â
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49,Â
DIN480201, JIS C3109, customer special specification also can be satisfied.Â
Printed Circuit Board (PCB) mechanically supports and electrically connects Electronic Components or electrical components using conductive tracks, pads and other features etched from one or more sheet layers of copper laminated onto and/or between sheet layers of a non-conductive substrate. Components are generally soldered onto the PCB to both electrically connect and mechanically fasten them to it.
Printed circuit boards are used in all but the simplest Electronic Products. They are also used in all kinds of electrical products
Printed Circuit Board
Printed Circuit Board,Multilayer Printing Circuit Board,Motherboard Printed Circuit Board,Professional Printed Circuit Board
Orilind Limited Company , http://www.orilind.com