Application
ELC1-F series AC Contactor is applicable to the circuits up to the rated voltage 1000VAC 50Hz or 60Hz rated current up to 780A. It can be used for long distance breaking circuit and frequently starting or controlling the motor. It also can be used for the control of distribution circuits of rated current from 200A to 1600A.
Specification
 
Type
Conventional
Resistive
Current(A)
Rared current                                 Maximumpower of controlled AC-3
(A)                                                  squirrel motor (KW)
380V         660V              1000V                380V    660V  1000V
ELC1-F115 200 115 65 40 55 80 65
ELC1-F150 200 150 80 50 75 100 65
ELC1- F185 275 185 95 65 90 110 100
ELC1- F225 275 225 115 80 110 129 100
ELC1- F265 315 265 150 95 132 160 147
ELC1- F330 380 330 185 115 160 220 160
ELC1- F400 450 400 225 150 200 280 185
ELC1- F500 630 500 265 185 250 335 335
ELC1- F630 800 630 300 225 335 450 450
ELC1- F780 1000 780     400 475 475
 
Type
Mechanical endurance AC-3 Electrical endurance Back up fuse(SCPD)

Operating
Frequency h-1   
                              TimesX104
Operating
Frequency  

                             TimesX104
Specication         Rated current
ELC1-F115  
12w
 
1000
 
12w
 
120
RT16-2 50
ELC1-F150 RT16-2 355
ELC1- F185    
1w
RT16-2 425
ELC1- F225 RT16-2 500
ELC1- F265  
6w
   
6w
  RT16-2 630
ELC1- F330 600 RT16-2 800
ELC1- F400    
60
RT16-2 800
ELC1- F500 RT16-2 1000
ELC1- F630 600   600   RT16-2 1250²
    Electricalendurancefor control of AC-4 is available if required.Special order.
 

Application
ELC1-F series AC Contactor is applicable to the circuits up to the rated voltage 1000VAC 50Hz or 60Hz rated current up to 780A. It can be used for long distance breaking circuit and frequently starting or controlling the motor. It also can be used for the control of distribution circuits of rated current from 200A to 1600A.
Specification
 
Type
Conventional
Resistive
Current(A)
Rared current                                 Maximumpower of controlled AC-3
(A)                                                  squirrel motor (KW)
380V         660V              1000V                380V    660V  1000V
ELC1-F115 200 115 65 40 55 80 65
ELC1-F150 200 150 80 50 75 100 65
ELC1- F185 275 185 95 65 90 110 100
ELC1- F225 275 225 115 80 110 129 100
ELC1- F265 315 265 150 95 132 160 147
ELC1- F330 380 330 185 115 160 220 160
ELC1- F400 450 400 225 150 200 280 185
ELC1- F500 630 500 265 185 250 335 335
ELC1- F630 800 630 300 225 335 450 450
ELC1- F780 1000 780     400 475 475
 
Type
Mechanical endurance AC-3 Electrical endurance Back up fuse(SCPD)

Operating
Frequency h-1   
                              TimesX104
Operating
Frequency  

                             TimesX104
Specication         Rated current
ELC1-F115  
12w
 
1000
 
12w
 
120
RT16-2 50
ELC1-F150 RT16-2 355
ELC1- F185    
1w
RT16-2 425
ELC1- F225 RT16-2 500
ELC1- F265  
6w
   
6w
  RT16-2 630
ELC1- F330 600 RT16-2 800
ELC1- F400    
60
RT16-2 800
ELC1- F500 RT16-2 1000
ELC1- F630 600   600   RT16-2 1250²
    Electricalendurancefor control of AC-4 is available if required.Special order.
 