Briefly describe the maintenance route of fire lighting

Automatic charging function After the mains supply is normal, the battery is charged after step-down, rectification and filtering. The charging current is less than 400mA. Each battery of the automatic charging protection circuit has the highest voltage limit, and the maximum allowable voltage of the battery of 6V4Ah is 7.5V. The maximum allowable voltage of this luminaire is 7.2V, and the lamp with automatic protection function extends the service life of the battery and increases the number of repeated charge and discharge cycles. The protection measures of CCFL luminaires are different from those of common luminaires on the market.

KA1 does not work (refers to the voltage is not applied at both ends) KA11 normally closed, add 8.7V voltage, charge the battery through KA11 and 10 resistance, I charge max=8.7-5.1(V)10=0.36A=360mA, BG1 at this time The Vbe<0.7V is off and the KA1 has no voltage and does not work. As the battery voltage rises, when it rises to a certain height, the Zener diode breaks down and remains at 5.1V. When VR3>0.7V, BG1 is turned on, KA1 works, and KA11 changes from closed to open. Charging stops. Over-discharge protection circuit When the battery discharges to the load, the battery voltage is too low, which will affect the next re-charging. After repeated cycles, the battery life will be shortened, which will affect the service life of the lamp. This lamp over-discharge protection circuit.

When the battery voltage is higher than 5.1V, the voltage regulator tube breaks down and BG2 turns on. At this time, KA2 works, KA22 closes, the battery discharges through the KA22, and the lamp emits light. When the battery voltage drops below 5.1V, Vsez< 0.7V, the triode is cut off, KA2 has no electricity and does not work, KA22 turns from closed to open, the battery stops supplying power to the load, and the lamp does not emit light. After the mains supply is normal, recharge the battery for later use. The oscillating drive circuit raises the secondary voltage of the transformer to about 800V through the oscillating coupling circuit, and starts the lamp. After the lamp point, the voltage drops to about 230V, mainly through high frequency and high voltage, low current illuminating the lamp, and the surface brightness of the lamp High, no flicker.

Main performance indicators of CCFL fire emergency lights The main performance indicators of CCFL fire emergency lights are shown in the table below. Operating frequency (kHz) Total power (W) Power supply voltage (V) Emergency time (h) Conversion time (s) Start voltage (V) Operating waveform Maximum charging current (mA) 505620.5800 Sine wave 4004 Example One engaged in CCFL fire emergency light The sales salesman accidentally dropped the sample from the car on the concrete floor on the way of sending the sample. When he picked it up, he found that other performances were not affected except for slight damage to the lamp housing. It can be seen that CCFL fire luminaires can be widely used in various vibration situations. The luminaire was the first in the local fire department at some of the sales locations. Summarize CCFL fire emergency lights, with perfect functions and reliable quality. The indicators meet the GA5493 standard issued by the national public security department, and have withstood the severe test of the market for several years.

Special cables are special-purpose cables that can be used on specific occasions, such as high-temperature resistant, acid and alkali resistant, termite resistant, and wire and cable used in ships, ships, nuclear power stations and other occasions. In terms of classification, it does not belong to the same classification method as power, control, computer cables, etc., that is, the cables listed above also include special cables. General special cables need to set internal control standards.


Introduction

Special cables are special-purpose cables that can be used in specific applications, such as high-temperature resistance, acid and alkali resistance, termite resistance, and wire and cable used in ships, ships, and nuclear power stations. In terms of classification, it does not belong to the same classification method as power, control, computer cables, etc., that is, the cables listed above also include special cables. General special cables need to set internal control standards.

Special cables are a series of products with unique properties and special structures. Compared to ordinary wires and cables with a wide range of products, they have higher technical content, stricter conditions of use, smaller batches and higher added value. New materials, new structures, new processes and new design calculations are often used.

classification

High temperature resistance

Aerospace, locomotive and rolling stock, energy, iron and steel, non-ferrous metal smelting, oil extraction, electrical machinery, construction and other fields require high-temperature wire and cable. Long-term continuous working temperature 125, 135, 150, 180, 200, 250 and 250 degree heat resistant wire and cable, commonly used irradiation cross-linked polyolefin, silicone rubber, fluorine resin, polyimide Amine, mica, magnesium oxide and other wire and cable. Now introduced; two new high-temperature wire and cable.

1. Polyether sulfone (PES) insulated wire

Has excellent heat resistance, physical and mechanical properties, electrical insulation properties, extrusion molding, especially in the environment can be used at high temperatures and rapid temperature changes in the environment can still maintain stable performance and other outstanding advantages: heat distortion temperature in 200 -220 degrees, continuous use temperature is 180-200 degrees, UL temperature index is 180 degrees; resistant to 150-160 degrees of hot water or steam, free from acid and alkali erosion at high temperature; elastic modulus is -100-- 200 degrees is almost constant, especially at 100 degrees or more than any thermoplastic resin; linear expansion coefficient is small, and its temperature dependence is also small; has no toxicity, is approved by the US FDA, and also complies with the Japanese Ministry of Health and Welfare No. 434 and The requirements of Announcement No. 178; self-extinguishing, without adding any flame retardant, has excellent flame retardancy, up to UL94V-0 (0.46mm).

2. Polyether ether ketone (PEEK) insulated wire

Polyetheretherketone is a superheat-resistant thermoplastic resin. The long-term continuous use temperature is 250 degrees and the UL temperature index is 250 degrees.

PEEK is a flexible resin with good creep resistance. And self-extinguishing, without any flame retardant up to UL94V-1 grade (thickness of 0.3mm), 94V-0 (thickness of 1.5mm), 94V-5 (thickness of 3.2mm) requirements.

Special folding structure

Low inductance cable

There is a difference between strong and weak electricity. Here we introduce a low-intensity cable for strong electricity. This cable is equipped with a heat dissipation device for a variety of new types of water-cooled low-inductance cables that are connected between contact welders, arc welders and pneumatic welding pliers. It has a simple and reasonable structure, large cooling water flow, no blockage. Blocking and current limiting phenomena, good heat dissipation, long service life, etc.

This new type of low-inductance cable also includes connectors fixed on the ends of the cables and cables, and the cable is also composed of a positive core cable and a negative electrode core in the outer rubber tube. Since such low-inductance cables are generally used in applications where the voltage is 25-50V and the current is between 70001 to 12000A, the short-circuit conduction of cooling water in the cable is basically negligible, so there is no such low-inductance cable. The use of a rubber hose that separates the positive and negative cores, except that a core frame with a spoke-like cross-section (commonly known as a "plum") is provided, and the "round center" and adjacent "spokes" The resulting space forms a longitudinal groove in the direction along the axis, and the longitudinal grooves on the core frame are the same as the total number of the positive electrode cores arranged on the cable. The cable portion is the positive and negative cores, respectively. The longitudinal groove device of the core holder is formed in the outer rubber tube. The two ends of the positive electrode core and the negative electrode core are respectively bundled and clamped into the cable clips and then fixed on the connector. The end of the outer hose of the cable is set on the tail end of the connector and used. Tighten the seal tightly outside the outer hose.

2. Low noise cable

In the bending, vibration, impact, temperature changes and other external factors, the cable itself is less than 5mV pulse signal cable is called low noise cable, also known as anti-vibration instrument cable. Used for the measurement of tiny signals in many fields such as industry, medicine, and defense. There are various types of cables such as polyethylene insulated low noise cable, F46 insulated low noise cable, radiation resistant low noise cable, low capacitance low noise cable, hydrophone cable, watertight low noise cable and so on.

The causes of noise in the cable are: 1) internal molecular friction in the medium; 2) change in cable capacitance; 3) piezoelectric effect in the cable medium; 4) friction in conductors and dielectrics in the cable, ie when between the conductor and the insulation The separation of charge occurs when the contact is broken.

A layer of thin, semi-conducting (0.20-0.30mm thick) low-noise cables has been rapidly developed on polyethylene insulation surfaces. The noise level is 2-3mV. For low noise cables working at 400 degrees, it can be used. High-temperature semi-conductive fiber wrapped around the package to solve the noise up to 5mV.

1. Fluorocarbon resin self-control stability 135 degree heating cable

135 degree self-control temperature cable composed of polyvinylidene fluoride (PVDF) / fluororubber alloy / carbon black multiple compound. The thermal process is different, showing different degrees of PTC conductive properties and electrical conductivity stability, this is due to the degree of crystallinity and crystal morphology of the substrate is affected by different cooling speed insulation.

2. Electroluminescent wires

Electroluminescent wire is the latest product in the field of international light emitting display. Its appearance is similar to that of ordinary wire and cable. The surface is a color fluorescent plastic sleeve. Its operation is continuous without any heat radiation, and the power consumption is only 50-60% of the LED lamp. 20-30% of string lights are 1-5% of neon lamps; these products are widely used to create a new era of energy saving, environmental protection, and healthy display lighting, with the following characteristics:

1) Light and delicate, bright colors, strong three-dimensional and perspective, suitable for night visual inspection.

2) Energy saving, environmental protection and safety; The product has low power consumption and a wide range of applicable voltages. The use and disposal of this product will not produce any environmental pollution, and will not pose a danger to humans.

3) Flexible, foldable and bent, free to knot, splicing, splicing, without affecting the luminous performance, easy to use, and installation without professional guidance.

4) It is a continuous light emitting device, and it can simultaneously control the dynamic multi-color flashing according to the telephone control and match.

5) Scotch tape, glue, pins, thread nails, etc. can be directly attached to the surface of the decorative object.

The application fields of this wire are:

1) Indoor advertising, text design; showcases, doors, furniture, walls, roofs, etc.

2) Cars, boats and other tools decoration; instrument instructions, digital display.

3) Safety signs and instructions; stairways, passageways, house signs, exits, temporary outdoor dangerous sites.

4) Toys, arts and crafts, sporting goods, clothing, electrical appliances, decoration, and military equipment.

Green insulation and environmental protection

1.CMP cable

Cables that pass UL's highest flame rating standards are CMP cables. A large number of combustible tests on wires and cables made by Du Bang, Langxun, and BICC jointly showed that a thin layer of FEP (F46) sheathing was extruded on the outside of ordinary cables to satisfy this requirement.

In general, low-smoke, halogen-free substrates are polyolefins, which have high fuel heat and are highly flammable, so they are mixed with metal hydrate fillers to inhibit their flammability, but hydration water After exhaustion, it will cause fierce combustion. The heat of combustion of FEP is very small and it does not burn in the event of fire.

2. Halogen-free new green wire and cable

Special Cable

Special Cable,High Current Cables,High Voltage Cable,Robot Control Cable

Jiangsu QiSheng Cable Co., Ltd. , https://www.shuaihe-cable.com